FP-08450 Control Panel FP-08451 Control Panel FP-08850 Delayed Discharge FP-08860 Shutdown Module FP-08800 Test Simulator FP-08825 Thermal Fuse VSS
Control Panel • Manual or Auto operation ▪ Twin power supply ▪ 2 Detection circuits – works with Thermal ROR, smoke detectors, or LHD ▪ All circuits monitored ▪ Options for delayed or 2nd shot and Shutdown relay ▪ 12-24vDC ▪ Compliant to NSCV. Control Panel. Features ▪ Manual or Auto operation ▪ Twin power supply available ▪ 2 Detection circuits – works with Thermal ROR, smoke detectors, or LHD ▪ All circuits monitored ▪ Options for delayed or 2nd shot and Shutdown relay ▪ 12-24vDC. Delay Discharge Module allows for the addition of FirePro Generators above the limit of 4 in the standard panel. Also provides for delayed discharge of units should longer agent discharge time is required ▪ All circuits monitored. Shutdown Module – connects via the siren circuit, and will allow for selectible delays for the shutdown of devices. It Provides a volt Free Contact (NO or NC) which can be used with appropriately rated relays. This test unit is used to check wiring connections. Used in commissioning and testing of the systems. Each system has different requirements for this device – check manual for correct selection. Thermal Fuse – connects to Model 08451 FIP, provides a system discharged advice, as required by AS5062.
FP-08879 Voltage Sensitive Relay FP-08945 Anti-Tamper – IP67 FP-08458 2/4 Zone Detection Panel FP-08872-3 12/24v NiMH Power FP-08944 Siren Consolidation FP-14020 Dual Power Cable
Digital Voltage Sensitive Relay provides a plug-in solution for DC power supply. Monitors and automatically isolates the incoming power supply when the power drops below an operating voltage. This avoids deep discharge of batteries Anti-Tamper Enclosure – IP67 suits FP-08450/1 Control Panel ▪ Waterproof ▪ Hinged lid enclosure with gasket ▪ Made from ABS plastic ▪ Anti-Tamper Seal can be fitted ▪ Clear polycarbonate cover ▪ Dimensions: 135 x 185 x 100 mm. 2/4 Zone Detection System Control Panel.Features ▪ Twin power supply inputs available ▪ 2/4 Detection circuits – works with Thermal ROR, smoke detectors, or LHD ▪ All circuits monitored ▪ Compliant to NSCV. 12/24v NiMH Battery a plug-in, supplementary power supply to be installed with the FP-08450/1 Fire Control Panel. The Module provides continuous power to the control panel, as per AS5062, in the event the main power supply fails. Siren Consolidation Module used with FP-08450/1 Control Panels to monitor and operate a singular siren circuit. This module is for use in installations where multiple control panels have been installed, but individual sirens per panel are not required. Dual Power input Cable used where the installation has 2 separated power supplies available – e.g. vehicles with dual battery systems. This satisfies the AS requirements for backup battery, saves installing additional battery module.